GE Front Load Washer

9 Main Control Board #5

Juan Morales explains how to interpret wire color and gauge codes on GE washing machine schematics and verify the drain pump's 120V AC supply. Learn how voltage testing helps distinguish between drain pump and main control board failures, reducing unnecessary parts replacements, repair costs, and diagnostic time.
Multimeter
Electrical Schematics
Appliance Troubleshooting
How did you like this video?
Transcript

 Now you see pin number two is line pin number three is neutral, and they say C 20 and B 20. What that actually means if we look at the table over to the left, okay, the letter is gonna be the color of the wire and the number is the gauge.

So C dash 20 would be, if we look at the table, right? C is actually brown. And I believe the reason, the reason we do that is because C is uh, or, or. Like chocolate is brown. So we basically say C is always gonna be brown. And uh, the neutral line is B 20, so that would be black, right? If you look at the letter of B, it, it means black.

Now the gauge of the wire is gonna be 20. So this is essentially a. 20 gauge brown wire and a 20 gauge black wire. And of course, that's what you'll see. You'll see brown and a black wire. Now in your world it is not gonna look, um, like this, right? The the board is not gonna have an open connector. It's actually, actually gonna look like this right here.

Okay? You're actually going to see a connector attached to the board and there's your brown wire and your black wire. So tho those would be pin number two and three. And if you place your multimeter leads across pins. Two and three and you start the drain pump, guess what you're gonna see right there?

120 volts ac. All right. And this is so great because now you can troubleshoot, right? If you have a no drain situation, you know, when I was a tech, I would say, well, let me swap out the drain pump and the main board and call it a day. But I was actually. Maybe wasting money in in parts because what if it was just a main board that wasn't supplying voltage?

Well, if I measured it, then I would get my one 20. But what if the drain pump was the one that was bad? Well. I didn't really know that because I just swapped them out and I just basically wasted a very good, you know, a perfectly good main control board for no reason whatsoever. If you are in property management, my friends, and you are swapping out parts and you're not troubleshooting, you are costing your company thousands and thousands of dollars because swapping out parts is easy.

Troubleshooting is not, but troubleshooting is gonna save you a ton of money in the long run, believe me when I tell you this.