20 Motor Diagnose #2
So connector 5 0 6 is the connector that will send. Neutral and AC signal to the inverter board. And the way it's gonna do that is on pins two and three. So you can see. PIN number two is your neutral and pin number three is your switched. Very important word. Switched AC line. Of course. PIN number one is ground.
Now the reason it is switched my friends, is because the main control board does not. Constantly send voltage to the inverter. Okay? That one 20 volt AC is not always, always, always there. Otherwise, we, we'd be wasting a lot of electricity. The one 20 volt AC is only sent to the inverter board whenever the motor needs to run.
That's the only time. So whenever the, you know, there's an agitate action or spin action, that's when the 120 volts AC see. Turns on at the main and gets sent to the inverter board. The way you would measure that, all right, is you would place your multimeter leads between pins two and three. So let's show a a picture of what that looks like over here.
So there it is. There's your multimeter on the connector. 5 0 6, pins number two and three, which is gonna be a white. And a black wire. Okay, so the white wire is the neutral. The black wire is the switched AC line. Now, if you place your multimeter leads between pins two and three, just like we're showing over here.
What's gonna happen is if the motor is not running, it's not spinning or agitating, then your multimeter will read, uh, zero volts ac. But as soon as you turn on that motor right to either agitate or spin, guess what? Your multimeter is gonna switch to 120 volts ac. Now we're showing 1 22 because that's what's coming from the outlet in this particular example.
But you could see that my friends. Okay, so no volt, no uh, no spin or no. Agitate action. Zero volts if you spin or agitate 120 volts ac. Now another thing is how are you gonna actually turn on that, that voltage? Well, you could do it a couple different ways. You could go into service mode and find the test that activates the motor and.
And do that. But again, it's complex. You could also just simply hit the start key, wait for the drain pump to go on first, and then the motor eventually will kick, you know, will turn on. But it can also be a little bit cumbersome. So we're gonna show you how, if you use the Smart HQ service application with a push of a button, you can actually engage that voltage on, off, on, off as many times as you want so you can have an accurate, uh, view of exactly when the voltage is coming.
Um, from the main board and when it's, when it's not. So you can see if the main board is, is good or bad. Okay? But again, we're gonna get, uh, get into that last over here. Most important thing is where to place your multimeter leads. And again, reiterate pins number two and three, that's gonna be a black and a white wire.
And if you turn on the agitate or spin action, you should get 120 volts ac. So with that said, my friends, that's pretty much the only thing you're gonna be able to test. Alright? You can't test. Remember I said you cannot test the DC uh, variable DC coming out of the inverter. Now what you can test though, is the windings on the motor.
So. Let's put it this way, if your motor windings are good, you get three and a half homes consistently across the three. You are getting 120 volts ac, see from your main to the inverter. But there's still a problem with the motor not spinning. More than likely, the problem is gonna be your inverter board.