Juan Morales demonstrates how to access electrical schematics and resistance tables using SmartHQ Service. Learn how to locate manufacturer resistance specifications, identify multimeter testing points, and test drive motors, drain pumps, and water valve solenoids on GE front-load washing machines to accurately diagnose component failures.
Maintenance Training
Electrical Schematics
Appliance Troubleshooting
How did you like this video?
Transcript

 But with Smart HQ service, you can actually pull up that information on the mini manual. So, uh, let's go ahead and find that. So from the dashboard screen, you're gonna go ahead and select manuals and bulletins, and then we're gonna go ahead and click mini manual right there, mini manual.

And that. Brings up the schematic diagram, so now we can go ahead and pinch. There's a lot of information now, obviously there, right? We're not gonna look at all that, but now you can go ahead and pinch to zoom and locate that schematic diagram. See there's your table for the colors. And look at the crystal clear quality of the graphics.

My friends, this is. Just amazing. Right? Very easy to read. Very easy to find. There's your drain pump. There's connector J 5 1 2. So like I said, I, I'm a, you know, I got everything from here. Everything that I'm showing you, there's your door lock, there's your water valves right there. Right, the ones we were talking about.

So all the information can be easily found right from the Smart HQ service application. Make sure you take a look at it, you leverage it. This is where everything that you need will be, will be found. Okay? So again, uh, enough of that. Let's go back over here to the s schematics sim, uh, diagram and look at the resistance table.

So if we look at the resistance table, we can, uh, look at the first component, the drive motor. It is 3.5 ohms and, uh, it's got a tolerance of plus or minus 7%. Now that's gonna be across the three windings, which is the red, white, and blue wires. If you look at the water valve coil, which is, uh, the, the solenoids, that's gonna be 1070 ohms.

So that's what you're looking for about one K. And if we look at a drain pump motor at the bottom, it's about 19 and a half ohms. So. Let's zoom out over here and take a look at the, let's zoom into the motor. If I wanted to to check that. Three and a half ohms right at the motor. Okay. I mean, physically at the motor itself, I would have to go right to those, those wires right there.

The red, white, and blue. Put my multimeter in. Ohms Reading, right? Resistance in check between any of the combinations for three and a half. Oms, any of them are bad. Guess what? I have to replace the motor. If we were to do the same thing with our drain pump over here, alright, I would go to those two kind of like holes at the top that you see right there.

And if I place my leads, uh, right there, my ome, it should read about 19.5 ohms. And the same thing for the water valves. Uh, you can go actually right to the right to the pins right here across any of these two. And you should get about 1,070 ohms in each one. So that's. That's where you would go physically on the actual component.